cupotential-openmm
Adapt an OpenMM simulation to cuPotential, run NVT or NPT, and save or resume checkpoints while preserving the supplied force field and simulation settings. Use for nv_openmm_plugin force replacement, simulation setup, parameter changes, and restart problems.
Try your first task
A source-grounded starter task has not been verified for this skill yet.
SKILL.md
name: cupotential-openmmdescription: Adapt an OpenMM simulation to cuPotential, run NVT or NPT, and save or resume checkpoints while preserving the supplied force field and simulation settings. Use for nv_openmm_plugin force replacement, simulation setup, parameter changes, and restart problems.license: Apache-2.0metadata: author: Ohad Mosafi <omosafi@nvidia.com> tags: [cupotential, openmm, molecular-dynamics, checkpoints] status: alpha version: "0.1.0"Run OpenMM simulations with cuPotential
Produce an adapted simulation and evidence for the requested execution or restart. Use the user's application and selected interpreter; installed-plugin users do not need a cuPotential source checkout.
The upstream library is NVIDIA/cuPotential. This skill was reviewed against v0.3.5; match version-specific behavior to the user's selected runtime.
Instructions
Establish the simulation contract
Inventory the input System, coordinates, box, forces, exceptions, constraints, virtual sites, masses, precision, integration settings, and requested ensemble. Keep an independent stock System for comparisons. Preserve supplied files. Determine whether the task requests a force replacement alone or also cuPotential's integrator and barostat. The blog's example settings describe its benchmark system; retain the user's timestep and hydrogen-mass/constraint policy.
Read conversion, execution and restart for the chosen operation. Confirm the installed release's supported source methods and numerical settings before converting. The reviewed 0.3.5 API accepts standard PME/LJPME conversion with its fixed numerical policy; it does not accept arbitrary pinned meshes or accuracy targets. Explain incompatible requirements before changing them. Geometry restrictions also need checking for the supplied box and cutoff.
CPU reference fallback
When CUDA/cuPotential is unavailable and a CPU fallback is permitted, run a
separate stock OpenMM control on CPU or Reference, preserving the input model.
Keep the stock integrator, COM remover and, for NPT, stock barostat in that control.
The CPU procedure and bundled
scripts/run_cpu_reference.py exercise energy/forces and a fresh-process restart.
An isolated stock OpenMM installation is an option when package changes are allowed.
Label its result CPU_REFERENCE_PASS or CPU_REFERENCE_FAILED and record
cuPotential/CUDA as NOT_RUN. A stock checkpoint does not test native cuPotential
serialization, COM transfer or barostat state. Prepare those conversions separately.
If the request requires CUDA, the requested cuPotential execution remains incomplete.
Retain failed attempts; use python -B to avoid bytecode cache cleanup.
Adapt and execute
Construct each replacement before removing its source force, and replace it once. OpenMM owns and deletes removed forces: extract everything needed from a source before removal. Preserve untouched forces and particle ordering. Check the final inventory for omissions and double-counting.
If replacing the integrator, transfer the existing center-of-mass removal policy explicitly; cuPotential's default frequency can otherwise introduce a change. If retaining the stock integrator, retain its remover. Use one intended barostat, preserving pressure, temperature, frequency, and the requested seed policy.
Create the Context only after configuring the System. Observe initial finite
energy/forces, then execute the requested duration with appropriate reporting and
checkpoint output. Global value changes use Context.setParameter; supported
particle values use updateParametersInContext. Changes to force structure,
expression layout, or certain policies require reinitialization.
Verify the requested outcome
Check state restoration in a fresh compatible Context when restart is requested. Distinguish restored positions, velocities, box, time and parameters from identical future stochastic trajectories, especially for NPT barostat bookkeeping.
Report actual steps and outputs, preserved settings, deliberate changes and unresolved errors. A running simulation or a restored checkpoint does not establish numerical accuracy; compare fixed configurations when accuracy is part of the task.
Examples
Request: "Convert my periodic OpenMM simulation to cuPotential, retain my NPT settings, run 1,000 steps, and verify a checkpoint restart."
Use the conversion and restart procedure. Return the adapted script, before/after force inventory, observed step count and checkpoint restoration checks from a fresh compatible Context. Preserve the supplied thermostat, barostat and COM policy unless the request changes them.