← LeaderboardThe Skill Leaderboard

matrixqcvis

Skill file skills/proteomics/matrixqcvis/SKILL.md in bioMate-AI/biomate-bioconductor-kb. Read the publisher’s upstream source.

Description awaits a fresh source check.

Published by bioMate-AI ↗bioMate-AI/biomate-bioconductor-kb

Try your first task

bioconductor-matrixqcvis

Start a fresh conversation. Replace the highlighted placeholders.

Use bioconductor-matrixqcvis to review [SummarizedExperiment object] in an interactive MatrixQCvis quality-exploration session, checking missingness, distributions, drift, outliers, and dimension-reduction evidence before selecting any processing or batch-correction steps.

Required inputs

  • [SummarizedExperiment object]

User-approved starter prompt based on a pinned source version; check current skill requirements before running. Task evidence ↗

SKILL.md

name: bioconductor-matrixqcvisdescription: Data quality assessment is an integral part of preparatory data analysis to ensure sound biological information retrieval. We present here the MatrixQCvis package, which provides shiny-based interactive visualization of data quality metrics at the per-sample and per-feature level. It is broadly applicable to quantitative omics data types that come in matrix-like format (features x samples). It enables the detection of low-quality samples, drifts, outliers and batch effects in data sets. Visualizwhen_to_use: Use when: Shiny-based interactive data quality exploration of omics data; Metabolomics data analysis (MatrixQCvis); Proteomics quantification (MatrixQCvis); Quality control and preprocessing (MatrixQCvis). Not for: Requires R ≥ 4.0.0 and Bioconductor ≥ 3.16user-invocable: false

MatrixQCvis

Workflows

Standard Workflow

Data quality assessment is an integral part of preparatory data analysis to ensure sound biological information retrieval. We present here the MatrixQCvis package, which provides shiny-based interactive visualization of data quality metrics at the per-sample and per-feature level. It is broadly applicable to quantitative omics data types that come in matrix-like format (features x samples). It enables the detection of low-quality samples, drifts, outliers and batch effects in data sets. Visualiz

Steps:

  1. Samples measured/missing barplot
  2. Feature missingness histogram
  3. Feature missingness by condition
  4. UpSet plot of missingness across conditions
  5. Normalization
  6. Batch correction (default to none)
  7. Transformation (vsn with log2 fallback)
  8. Imputation (MinDet with minimum value fallback)
  9. CV comparison across processing stages
  10. Boxplot/Violin plot of processed values
  11. Drift Plot
  12. Distance Matrix Heatmap
library(MatrixQCvis)
library(SummarizedExperiment)
# Assuming 'se' is a SummarizedExperiment object
se_sds <- apply(assay(se), 1, sd, na.rm = TRUE)
se <- se[!is.na(se_sds) & se_sds > 0, ]
# Start the interactive Shiny application
# qc <- shinyQC(se)

Input: A SummarizedExperiment object. Output: An interactive Shiny application that returns a processed SummarizedExperiment object upon exit.

When to Use

  • Shiny-based interactive quality control and visualization of quantitative omics datasets (proteomics, metabolomics, transcriptomics).
  • Detecting low-quality samples, instrument drifts, outliers, and batch effects.
  • Performing simple differential expression analysis using moderated t-tests (limma) or Wald tests (proDA) directly within the Shiny interface.

When NOT to Use

  • For non-matrix-like data or raw sequencing reads (e.g., FASTQ files), use packages like ShortRead or FastQC.
  • For complex multi-factor batch correction or advanced linear modeling outside of interactive exploration, use limma or sva directly.

Data Requirements

  • A SummarizedExperiment object where rownames(se) are feature names, colnames(se) are sample names, and colnames(se), colnames(assay(se)), and rownames(colData(se)) are all identical.
  • Features with standard deviation of 0 should be filtered out before analysis.

Key Parameters

  • se: A SummarizedExperiment object containing the quantitative assay matrix and metadata.

Best Practices

  • Filter out features with a standard deviation of 0 using apply(assay(se), 1, sd, na.rm = TRUE) before launching shinyQC.
  • Consult dimension reduction plots (PCA, PCoA, tSNE, UMAP) before performing batch correction, rather than relying solely on value distributions.
  • Verify that sample names across colnames(se), colnames(assay(se)), and rownames(colData(se)) are identical to prevent errors.

Common Pitfalls

  • Launching shinyQC with rownames(se) or colnames(se) set to NULL: Ensure feature and sample names are properly assigned.
  • Performing batch correction based solely on boxplots/violin plots: Always inspect dimension reduction plots first to avoid over-correction.

Alternatives

  • limma for non-interactive batch correction and differential expression.
  • proDA for intensity-dependent probabilistic modeling of missing values in label-free proteomics.
  • sva for ComBat-based batch effect correction.

Citations

  • Ahlman-Eltze and Anders 2019, proDA (differential abundance analysis)
  • Ritchie et al. 2015, limma (moderated t-tests)

References

matrixqcvis by bioMate-AI · The Skill Leaderboard